City middle school building renovation

Through a master services agreement, EBI provided professional design services in support of the complete interior renovation of the 4,300 sq. ft. city middle school auditorium in Quincy, MA. Our team performed structural, mechanical, and electrical design and construction administration services to facilitate renovations to the auditorium. The middle school was originally built in 1956 and had been unaltered despite major flooding that occurred in 2016.

Facts and figures

  • 4,300 sq. ft. facility
  • Built in 1956

Challenges

Due to the conditions of the auditorium, a complete renovation was required. Our team provided administration services for the following renovations: removal and raising of the plaster ceiling renovation and reuse the stage and stairs, alteration of walls and ceilings for acoustic and stage lighting structural modifications for stage equipment support, and installation of new HVAC units and new control rooms.

Solutions

Our structural engineering team conducted a site visit prior to demolition to review the existing structure, coordinated calls and design meetings with the architectural and MEP teams, and worked with the architects of record (AOR) to incorporate all structural documents to ensure compliance. During construction, our structural engineers provided review and coordination to certify structural elements were constructed as designed. Our mechanical and electrical engineering professionals provided design development, construction documents and construction administration for the renovations. Design development consisted of extending new ductwork from roof penetrations for new distribution within the space. Our team developed new designs for lighting, fire alarm and power systems and ensured that all systems were designed to conform to Massachusetts State Building Codes. Our mechanical and electrical team worked cohesively with the architects to incorporate all mechanical and electrical needs, and to complete construction documents for permitting.

Outcomes

Our structural engineering team conducted a site visit post-demolition to ensure assessments were still concurrent and relative and worked with the AOR to ensure permitting.

Services Provided

  • Project management
  • Structural engineering
  • Mechanical/electrical engineering

Additional case studies

Telecom Excellence: Proactive Environmental Risk Management

EBI empowered a National Telecom Company to excel in environmental compliance, minimize liabilities, and operate confidently through integrated solutions for streamlined communication, risk assessment, real-time monitoring, proactive remediation, compliance analysis, staff training, and sustainable growth.
Read More

Tailored Expertise Transforms 25+ Hospitals Nationwide

EBI Consulting supports hospitals, assisted living facilities, biotech and pharmaceutical spaces, and medical offices in meeting their environmental, regulatory, and operational goals while ensuring compliance and reducing risks.
Read More

Engineering scientific breakthroughs: National Institutes of Health campus revamp 

EBI Consulting transformed NIH campuses in Research Triangle Park and Durham, North Carolina, with cutting-edge projects optimizing mechanical systems for scientific advancements.